Detector and column saturations are problematic in comprehensive two-dimensional gas chromatography (GC×GC) data analysis. This limits the application of GC×GC in metabolomics research. To address the problems caused by detector and column saturations, we propose a two-stage data processing strategy that will incorporate a targeted data processing and cleaning approach upstream of the “standard” untargeted analysis. By using the retention time and mass spectrometry (MS) data stored in a library, the annotation and quantification of the targeted saturated peaks have been significantly improved. After subtracting the nonperfected signals caused by saturation, peaks of coelutes can be annotated more accurately. Our research shows that the target-guided method has broad application prospects in the data analysis of GC×GC chromatograms of complex samples.

Zhang, P.; Carlin, S.; Franceschi, P.; Mattivi, F.; Vrhovsek, U. (2022). Application of a target-guided data processing approach in saturated peak correction of GC×GC analysis. ANALYTICAL CHEMISTRY, 94 (4): 1941-1948. doi: 10.1021/acs.analchem.1c02719 handle: http://hdl.handle.net/10449/72216

Application of a target-guided data processing approach in saturated peak correction of GC×GC analysis

Zhang, Penghan
Primo
;
Carlin, Silvia;Franceschi, Pietro;Mattivi, Fulvio;Vrhovsek, Urska
Ultimo
2022-01-01

Abstract

Detector and column saturations are problematic in comprehensive two-dimensional gas chromatography (GC×GC) data analysis. This limits the application of GC×GC in metabolomics research. To address the problems caused by detector and column saturations, we propose a two-stage data processing strategy that will incorporate a targeted data processing and cleaning approach upstream of the “standard” untargeted analysis. By using the retention time and mass spectrometry (MS) data stored in a library, the annotation and quantification of the targeted saturated peaks have been significantly improved. After subtracting the nonperfected signals caused by saturation, peaks of coelutes can be annotated more accurately. Our research shows that the target-guided method has broad application prospects in the data analysis of GC×GC chromatograms of complex samples.
Saturation
Beverages
Metabolomics
Chromatography
Ions
Settore CHIM/01 - CHIMICA ANALITICA
2022
Zhang, P.; Carlin, S.; Franceschi, P.; Mattivi, F.; Vrhovsek, U. (2022). Application of a target-guided data processing approach in saturated peak correction of GC×GC analysis. ANALYTICAL CHEMISTRY, 94 (4): 1941-1948. doi: 10.1021/acs.analchem.1c02719 handle: http://hdl.handle.net/10449/72216
File in questo prodotto:
File Dimensione Formato  
2022 AC Zhang.pdf

accesso aperto

Tipologia: Versione editoriale (Publisher’s layout)
Licenza: Creative commons
Dimensione 2.75 MB
Formato Adobe PDF
2.75 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10449/72216
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact