The development and application of new separation mechanisms such as hydrophilic interaction chromatography (HILIC) is of high importance for the simultaneous analysis of polar molecules such as primary metabolites. However the retention mechanism in HILIC is not fully understood and as a result retention prediction tools are not at hand for this chromatographic approach. In the present report we study the utility of a simple algorithm, based on a simple linear and/or a simple logarithmic retention model, for retention prediction in HILIC gradient separation of a mixture of 23 selected compounds including (poly) amines, amino acids, saccharides, and other molecules. Utilizing two types of gradient elution programs with or without an isocratic part, retention data were collected in order to build prediction models. Starting from at least three gradient runs the prediction of analyte retention was very satisfactory for all gradient programs tested, providing useful evidence of the value of such retention time prediction methodologies

Gika, H.; Theodoridis, G.; Mattivi, F.; Vrhovsek, U.; Pappa Louisi, A. (2012). Hydrophilic interaction ultra performance liquid chromatography retention prediction under gradient elution. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 404 (3): 701-709. doi: 10.1007/s00216-012-6015-6 handle: http://hdl.handle.net/10449/21031

Hydrophilic interaction ultra performance liquid chromatography retention prediction under gradient elution

Theodoridis, Georgios;Mattivi, Fulvio;Vrhovsek, Urska;
2012-01-01

Abstract

The development and application of new separation mechanisms such as hydrophilic interaction chromatography (HILIC) is of high importance for the simultaneous analysis of polar molecules such as primary metabolites. However the retention mechanism in HILIC is not fully understood and as a result retention prediction tools are not at hand for this chromatographic approach. In the present report we study the utility of a simple algorithm, based on a simple linear and/or a simple logarithmic retention model, for retention prediction in HILIC gradient separation of a mixture of 23 selected compounds including (poly) amines, amino acids, saccharides, and other molecules. Utilizing two types of gradient elution programs with or without an isocratic part, retention data were collected in order to build prediction models. Starting from at least three gradient runs the prediction of analyte retention was very satisfactory for all gradient programs tested, providing useful evidence of the value of such retention time prediction methodologies
Hydrophilic interaction chromatography (HILIC)
Gradient elution
Retention prediction
Polar analytes
Metabolomics
Settore CHIM/01 - CHIMICA ANALITICA
2012
Gika, H.; Theodoridis, G.; Mattivi, F.; Vrhovsek, U.; Pappa Louisi, A. (2012). Hydrophilic interaction ultra performance liquid chromatography retention prediction under gradient elution. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 404 (3): 701-709. doi: 10.1007/s00216-012-6015-6 handle: http://hdl.handle.net/10449/21031
File in questo prodotto:
File Dimensione Formato  
2012 ABC Gika et al.pdf

non disponibili

Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 377.34 kB
Formato Adobe PDF
377.34 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10449/21031
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 32
social impact