The analysis of amino acids presents significant challenges to contemporary analytical separations. The present paper investigates the possibility of retention prediction in hydrophilic interaction chromatography (HILIC) gradient elution based on the analytical solution of the fundamental equation of the multilinear gradient elution derived for reversed-phase systems. A simple linear dependence of the logarithm of the solute retention (ln k) upon the volume fraction of organic modifier (j) in a binary aqueousorganic mobile is adopted. Utility of the developed methodology was tested on the separation of a mixture of 21 amino acids carried out with 14 different gradient elution programs (from simple linear to multilinear and curved shaped) using ternary eluents in which a mixture of methanol and water (1:1, v/v) was the strong eluting member and acetonitrile was the weak solvent. Starting from at least two gradient runs, the prediction of solute retention obtained under all the rest gradients was excellent, even when curved gradient profiles were used. Development of such methodologies can be of great interest for a wide range of applications.
Gika, H.; Theodoridis, G.; Mattivi, F.; Vrhovsek, U.; Pappa Louisi, A. (2012). Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography. JOURNAL OF SEPARATION SCIENCE, 35 (3): 376-383. doi: 10.1002/jssc.201100795 handle: http://hdl.handle.net/10449/20689
Retention prediction of a set of amino acids under gradient elution conditions in hydrophilic interaction liquid chromatography
Theodoridis, Georgios;Mattivi, Fulvio;Vrhovsek, Urska;
2012-01-01
Abstract
The analysis of amino acids presents significant challenges to contemporary analytical separations. The present paper investigates the possibility of retention prediction in hydrophilic interaction chromatography (HILIC) gradient elution based on the analytical solution of the fundamental equation of the multilinear gradient elution derived for reversed-phase systems. A simple linear dependence of the logarithm of the solute retention (ln k) upon the volume fraction of organic modifier (j) in a binary aqueousorganic mobile is adopted. Utility of the developed methodology was tested on the separation of a mixture of 21 amino acids carried out with 14 different gradient elution programs (from simple linear to multilinear and curved shaped) using ternary eluents in which a mixture of methanol and water (1:1, v/v) was the strong eluting member and acetonitrile was the weak solvent. Starting from at least two gradient runs, the prediction of solute retention obtained under all the rest gradients was excellent, even when curved gradient profiles were used. Development of such methodologies can be of great interest for a wide range of applications.File | Dimensione | Formato | |
---|---|---|---|
2012 JSS Gika et al.pdf
non disponibili
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
203.06 kB
Formato
Adobe PDF
|
203.06 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.