Direct coupling of thin-layer chromatography (TLC) with matrix-assisted laser desorption ionization (MALDI) mass spectrometry allows fast and detailed characterization of a large variety of analytes. The use of this technique, however, presents great challenges in semiquantitative applications because of the complex phenomena occurring at the TLC surface. In our laboratory, we recently observed that the ion intensities of several alkali adduct ions were significantly different between the top and interior layer of the TLC plate. This indicates that the integrity of the TLC surface can have an important effect on the reproducibility of TLC- MALDI analyses. Graphical Abstract MALDI imaging reveals that surface integrity affects the detection of alkali adductions in TLC-MALDI

Dong, Y.; Ferrazza, R.; Anesi, A.; Guella, G.; Franceschi, P. (2017). TLC surface integrity affects the detection of alkali adduct ions in TLC-MALDI analysis. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 409 (24): 5661-5666. doi: 10.1007/s00216-017-0501-9 handle: http://hdl.handle.net/10449/42883

TLC surface integrity affects the detection of alkali adduct ions in TLC-MALDI analysis

Dong, Y.
Primo
;
Anesi, A.;Franceschi, P.
Ultimo
2017-01-01

Abstract

Direct coupling of thin-layer chromatography (TLC) with matrix-assisted laser desorption ionization (MALDI) mass spectrometry allows fast and detailed characterization of a large variety of analytes. The use of this technique, however, presents great challenges in semiquantitative applications because of the complex phenomena occurring at the TLC surface. In our laboratory, we recently observed that the ion intensities of several alkali adduct ions were significantly different between the top and interior layer of the TLC plate. This indicates that the integrity of the TLC surface can have an important effect on the reproducibility of TLC- MALDI analyses. Graphical Abstract MALDI imaging reveals that surface integrity affects the detection of alkali adductions in TLC-MALDI
TLC-MALDI
MS-Imaging
Alkali-metal ions
Lipid
Settore CHIM/01 - CHIMICA ANALITICA
2017
Dong, Y.; Ferrazza, R.; Anesi, A.; Guella, G.; Franceschi, P. (2017). TLC surface integrity affects the detection of alkali adduct ions in TLC-MALDI analysis. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 409 (24): 5661-5666. doi: 10.1007/s00216-017-0501-9 handle: http://hdl.handle.net/10449/42883
File in questo prodotto:
File Dimensione Formato  
2017 Franceschi.pdf

solo utenti autorizzati

Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10449/42883
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact