Many are the sources of variability that can affect reproducibility of disease biomarkers from time-of-flight (TOF) Mass Spectrometry (MS) data. Here we present TOFwave, a complete software pipeline for TOF-MS biomarker identification that limits the impact of parameter tuning along the whole chain of preprocessing and model selection modules. Peak profiles are obtained by a preprocessing based on Continuous Wavelet Transform (CWT), coupled with a machine learning protocol aimed at avoiding selection bias effects. Only two parameters (minimum peak width and a signal to noise cutoff) have to be explicitly set. The TOFwave pipeline is built on top of the mlpy Python package. Examples on Matrix-Assisted Laser Desorption and Ionization (MALDI) TOF datasets are presented.

Chierici, M.; Albanese, D.; Franceschi, P.; Furlanello, C. (2012). TOFwave: reproducibility in biomarker discovery from Time-Of-Flight Mass Spectrometry data. MOLECULAR BIOSYSTEMS, 8 (11): 2845-2849. doi: 10.1039/c2mb25223f handle: http://hdl.handle.net/10449/21512

TOFwave: reproducibility in biomarker discovery from Time-Of-Flight Mass Spectrometry data

Albanese, Davide;Franceschi, Pietro;
2012-01-01

Abstract

Many are the sources of variability that can affect reproducibility of disease biomarkers from time-of-flight (TOF) Mass Spectrometry (MS) data. Here we present TOFwave, a complete software pipeline for TOF-MS biomarker identification that limits the impact of parameter tuning along the whole chain of preprocessing and model selection modules. Peak profiles are obtained by a preprocessing based on Continuous Wavelet Transform (CWT), coupled with a machine learning protocol aimed at avoiding selection bias effects. Only two parameters (minimum peak width and a signal to noise cutoff) have to be explicitly set. The TOFwave pipeline is built on top of the mlpy Python package. Examples on Matrix-Assisted Laser Desorption and Ionization (MALDI) TOF datasets are presented.
Mass Spectrometry
Data Analysis
Spettrometria di massa
Analisi di dati
2012
Chierici, M.; Albanese, D.; Franceschi, P.; Furlanello, C. (2012). TOFwave: reproducibility in biomarker discovery from Time-Of-Flight Mass Spectrometry data. MOLECULAR BIOSYSTEMS, 8 (11): 2845-2849. doi: 10.1039/c2mb25223f handle: http://hdl.handle.net/10449/21512
File in questo prodotto:
File Dimensione Formato  
2012 MBS Chierici et al.pdf

non disponibili

Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.